Can I replace a 4500 Watt water heater with a 5500 Watt?
4500 Watt elements are plenty adequate. The purpose of 5500 watt would be to heat water faster, So the water heater delivers more hot water.Do not install 5500 watt element to replace 4500 watt element. Installing lower watt All new water heaters come with high density elements. Replace with high.Click to see full answer. Also, what size breaker do I need for a 5500 watt water heater?The math shows that 5500 watt water heater is well within the safe maximum for a 30 amp breaker and 10 gauge wire. When heat exceeds circuit breaker rating, then the breaker trips. A 30 amp breaker with 10 gauge wire has 80% safe maximum = 24 amps. 24 amps x 240 volt = safe maximum 5760 watts.Also Know, can you replace a 4500 watt heating element with a 5500 Watt? When selecting element, buy same wattage or less wattage keep volts the same. It is ok to install higher watt up to 5500 on 4500 watt heater if breaker is 30 amp and wire is 10 gauge. It is ok to install lower watt: replace 4500 with 3500 as long as voltage is same. People also ask, is a 5500 watt water heater better than a 4500 Watt? The higher the BTU input and efficiency, the faster the recovery. Electric water heaters typically have one 5,500-watt or two 4,500-watt elements. Two lower-kilowatt elements will heat much faster than one higher-wattage element.Can I replace a 3800 Watt water heater with a 4500 Watt?You can buy 3800 watt elements to replace the 4500 watt units. This is commonly done when the electric is NOT 10 gauge wire with 30 amp breaker. If it is 12 gauge and 20 amp you are limited to 3800 watt elements.